Firewood Calculator

Use this free firewood calculator to find how many cords you need for the winter, based on the fuel you use now or the wood you burned last year. It also estimates firewood from a tree or a log, and converts cords, face cords, loose piles and cubic feet. Jump to the tree and log calculator or the cord converter. Quick answer: 1 full cord = 128 cubic feet of stacked wood (4 × 4 × 8 ft), and a 16-inch face cord is one-third of a cord.

AI-generated illustration of a neat stack of split firewood under a covered rack beside a wood stove in a cabin on a winter evening
Illustration created with AI for this page. It is not a photo of a real woodpile.
Reviewed by · Published: October 13, 2026 · Sources: University extension · USDA Forest Service data · EIA · EPA
Firewood Calculator — How Many Cords Do I Need?
📐 Formula
Heat needed from wood = Fuel used × Btu per unit × System efficiency × Share from wood
Cords = Heat needed ÷ (Million Btu per cord × Wood appliance efficiency) × (1 + extra %)
Firewood to Buy
—
Enter your numbers above
Full Cords (128 cu ft)
—
Face Cords (16 in. deep)
—
Stacked Volume
—
Dry Weight (approx.)
—
Heat Needed from Wood
—
Est. Wood Cost
—
Wood Cost vs Current Fuel Cost
—

Estimates, not guarantees. Wood appliance efficiency and your home’s real heat loss vary, so keep the extra % for cold snaps. A cord is 128 cubic feet of stacked wood; ask sellers for the stacked volume.

Heat values are for wood seasoned to about 20% moisture.

Tree to Firewood and Log to Firewood Calculator

How much firewood is in a tree you plan to cut, or in a pile of logs? Choose standing trees (by trunk diameter) or cut logs (by diameter and length).

📐 Method
Trees: cords from the USDA Forest Service NED-2 table (via Cornell Cooperative Extension), interpolated by diameter × number of trees
Estimated Firewood
—
Enter a diameter above
Full Cords
—
Face Cords (16 in.)
—
Trees per Cord
—
Range
—

Tree estimates assume you use the main trunk and limbs down to about 4 inches in diameter (Cornell). Log estimates use the volume of a cylinder divided by about 80 cubic feet of solid wood per cord (range 65–90, University of Maryland); real yield is lower after bark, trimming and splitting waste. Freshly cut wood needs 6–12 months to season.

Cord of Firewood Converter — Face Cord, Loose Pile and Cubic Feet

Sellers use cords, face cords, truck loads and cubic feet. Enter the amount you were quoted to see the equal volume in stacked cords.

Equivalent in Full Cords
—
Enter an amount above
Full Cords
—
Face Cords (at that depth)
—
Stacked Cubic Feet
—
Stacked Cubic Meters
—
Loose Pile, 12–16 in. (cu ft)
—
Solid Wood (cu ft, approx.)
—

1 cord = 128 cu ft stacked (4 × 4 × 8 ft) · Face cord = 4 ft × 8 ft × the depth of one row of wood, so a 16-inch face cord is one-third of a cord and an 18-inch one is 37.5% · Loose piles: Maine’s legal “loose cord” is 180 cu ft for 12–16 in. pieces and 195 cu ft for 24 in. pieces; other places do not define it, so treat loose-pile figures as a guide · 1 stere (1 cubic meter) ≈ 0.276 cord

Firewood Heat Value by Species

Heavier hardwoods hold more heat per cord, so you need fewer of them. The table shows the heat in a full cord of wood seasoned to 20% moisture, its approximate dry weight, and how many cords of that species equal one cord of red oak.

SpeciesMillion BTU per CordWeight per CordCords = 1 Cord Red Oak
Hickory29.33,560 lb1.13
Black locust28.33,440 lb1.09
White oak27.93,392 lb1.08
Beech26.33,144 lb1.02
Sugar maple25.93,144 lb1.00
Red oak25.93,144 lb1.00
White ash24.62,992 lb0.95
Black walnut22.62,744 lb0.87
Black cherry20.52,496 lb0.79
American elm20.52,496 lb0.79
Sycamore20.22,448 lb0.78
Silver maple19.32,344 lb0.75
Virginia pine20.72,400 lb0.80
Yellow-poplar17.32,096 lb0.67
Hemlock17.32,000 lb0.67
Basswood15.21,848 lb0.59
White pine15.01,744 lb0.58

Values are for eastern species from the University of Kentucky table. Other sources, such as the University of Maryland, give slightly different numbers (for example, oak at 25.3 million BTU), because wood varies by tree, region and moisture. For western or other species not listed, pick the “Custom” option and use your supplier’s heat value, or the EIA average of 20 million BTU per cord.

💡 Tip

Wood that is not seasoned loses heat to boiling off water. Always burn wood at 20% moisture or less (check with a moisture meter), and treat the table as the heat you get from dry wood only.

Worked Examples

Example 1 — Replacing Half of an Oil Furnace’s Heat

800 gallons of heating oil a year, furnace 80% efficient, red oak (25.9 million BTU per cord) in an EPA-certified stove (70%), wood to supply 50% of heat, 10% extra:

Heat delivered by oil: 800 × 138,500 Btu × 0.80 = 88.64 million Btu

Heat needed from wood: 88.64 × 0.50 = 44.32 million Btu

Cords: 44.32 ÷ (25.9 × 0.70) = 2.44 cords; with 10% extra = 2.7 cords (about 8.1 face cords)

Example 2 — Switching Species

Last winter you burned 3 cords of white pine (15.0 million BTU) and plan to buy red oak (25.9):

3 × 15.0 ÷ 25.9 = 1.74 cords of oak for the same heat; add 10% = 1.9 cords

Example 3 — Trees on Your Lot

Six trees, each 14 inches across at breast height. The table gives 0.33 cords per 14-inch tree:

6 × 0.33 = 1.98 cords

Example 4 — A Cut Log

One log 16 inches across and 8 feet long:

Volume = π × (8 ÷ 12)² × 8 = 11.2 cu ft

Cords ≈ 11.2 ÷ 80 = 0.14 cord (range 0.12–0.17 cord using 90 and 65 cu ft of solid wood per cord)

Example 5 — A Loose Pile

A seller delivers a loose pile of 16-inch pieces measuring 180 cu ft:

180 ÷ 180 = 1 stacked cord (using Maine’s loose-cord definition). Re-stack to check.

For the cost of a stove or insert, see our Fireplace Insert Cost Calculator.

Buying and Measuring Firewood

  • Ask for the volume in cubic feet or full cords. A full cord is 128 cubic feet of wood stacked tightly (4 ft high × 4 ft deep × 8 ft long). Most US states define the cord by law.
  • Know what a “face cord” is. It is 4 ft × 8 ft by the depth of one row, commonly 16 inches (one-third of a cord) but sometimes up to 24 inches. Words like “rick” and “stove cord” have no single legal meaning.
  • Measure the delivered stack. Stack it tightly, then multiply length × height × depth in feet and divide by 128.
  • Check the moisture. Aim for 20% or less on a moisture meter. Gray, cracked ends and peeling bark suggest dry wood; heavy, wet or green wood needs a season or more.
  • Get a receipt showing the volume, species and price, and compare prices per full cord, not per load.
  • Buy local. Many places restrict moving firewood to limit the spread of tree pests; ask your state forestry agency.

Seasoning, Storing and Burning Firewood Safely

  • Season it. EPA advises at least 6 months for softwood and at least 12 months for hardwood, split to pieces about 6 inches across or smaller.
  • Stack it right. Keep wood off the ground, split side down, with air flowing through the stack and the top covered against rain and snow, but not the sides.
  • Burn dry wood only. Wet wood gives less heat and raises the risk of creosote build-up, which can cause a chimney fire.
  • Use a certified appliance. EPA says certified stoves use about one-third less wood for the same heat, and an open fireplace is a very inefficient way to heat a home.
  • Maintain the chimney. Have the chimney and flue inspected before the heating season (see our Chimney Repair Cost Calculator), keep working smoke and carbon monoxide alarms, and follow your appliance manual and local code.
⚠️ Safety

Wood heating carries fire and carbon monoxide risks. This page is general guidance. Have solid-fuel appliances installed and inspected by a qualified professional and follow local code and your insurer’s requirements.

Common Mistakes When Estimating Firewood

  • Mixing up a face cord and a full cord. A 16-inch face cord is one-third of a cord, so three face cords equal one cord.
  • Assuming all wood heats equally. A cord of pine can hold about half the heat of a cord of hickory.
  • Ignoring appliance efficiency. The same cord gives far less useful heat in an open fireplace than in an EPA-certified stove.
  • Buying green wood and burning it right away. Plan for 6–12 months of seasoning.
  • Forgetting the cold snaps. Keep 10–20% extra, since a cold winter can use far more than an average one.
  • Counting loose piles as cords. Loose wood contains more air than a tight stack; re-stack to check what you got.
  • Overestimating trees. The tree table assumes you use the trunk and limbs down to 4 inches and ignores waste.

How We Calculate

Fuel-based estimate. We convert your fuel into the heat it delivered: Fuel × Btu per unit × system efficiency. The Btu values come from EIA: heating oil 138,500 Btu per gallon, propane 91,452 Btu per gallon, natural gas 1,036 Btu per cubic foot (103,600 per ccf) and electricity 3,412 Btu per kWh. The default efficiencies (80% for combustion furnaces, 100% for electric resistance) are typical values you can change to match your equipment.

Wood needed. Cords = Heat from wood ÷ (Million Btu per cord × Wood appliance efficiency), then plus your extra percentage. Heat content by species is from the University of Kentucky table (wood at 20% moisture). Appliance presets of about 70% (EPA-certified), 50% (older stove) and 10% (open fireplace) are planning values; EPA notes that advertised stove efficiency is usually combustion efficiency and the overall figure may be 10–20% lower, so use a lower custom value if unsure.

Last winter’s wood. Cords this winter = Last winter’s cords × (Last species’ Btu ÷ New species’ Btu), plus extra. It assumes the same appliance and weather.

Trees. Cords per tree come from the Cornell Cooperative Extension table, built from USDA Forest Service NED-2 volume data (6 in. = 0.03 cord up to 22 in. = 1.0 cord). We interpolate between diameters and extend the last slope above 22 inches.

Logs. Volume = π × (diameter ÷ 2 in feet)² × length, divided by 80 cu ft of solid wood per cord (range 65–90).

Converter. 1 cord = 128 cu ft; face cord = depth ÷ 48 of a cord; 1 stere = 0.276 cord (1 ÷ 3.62); loose piles use Maine’s legal loose cords (180 cu ft for 12–16 in., 195 cu ft for 24 in.) as a guide.

ℹ️ How This Page Was Made

We use AI tools to help draft and format some content. The figures on this page come from the published sources listed below, and the formulas and examples were checked before publication. See our editorial policy.

Sources and References

The figures on this page were checked against the sources below in October 2026.

Published figures vary by source, species and region, so use these as a planning guide. ConstructlyTools has no paid relationship with any seller or manufacturer mentioned.

Frequently Asked Questions

How much firewood do I need for the winter?+
It depends on your home, climate, how much of your heat comes from wood and the efficiency of your stove. The calculator above estimates it from the fuel you use now. For example, replacing half the heat from 800 gallons of heating oil with red oak in an EPA-certified stove needs roughly 2.7 cords including a 10% reserve. If you burned wood last winter, use the “last winter” option instead, and keep some extra for a colder-than-usual season.
A full cord is 128 cubic feet of tightly stacked wood, traditionally 4 feet high, 4 feet deep and 8 feet long. Because of the gaps between pieces, only about 65–90 cubic feet of that is solid wood (University of Maryland Extension). Most US states define the cord by law, so a seller who says “cord” should deliver 128 stacked cubic feet.
A face cord is 4 feet high and 8 feet long by the depth of a single row of wood. With 16-inch pieces it is one-third of a full cord (about 42.7 cubic feet); with 24-inch pieces it is half. Because the depth varies, always ask the seller for the piece length and the total cubic feet. The converter above handles any depth.
Three face cords with 16-inch pieces make one full cord, and two face cords with 24-inch pieces make one. In general, face cords per cord = 48 ÷ depth in inches.
A loose or thrown pile has more air than a tight stack, so it takes more volume than a stacked cord. Maine, the one state that defines a “loose cord” by law, sets it at 180 cubic feet for 12- to 16-inch pieces and 195 cubic feet for 24-inch pieces, versus 128 cubic feet stacked. Use those figures as a guide, and re-stack a delivered pile to measure what you really received.
A tree 14 inches across at breast height yields about 0.33 cord, a 20-inch tree about 0.73 cord and a 22-inch tree about 1 cord, assuming you use the trunk and limbs down to 4 inches in diameter (Cornell Cooperative Extension, from USDA Forest Service volumes). Smaller trees yield far less: it takes about 33 trees of 6 inches to make a cord. Use the tree-to-firewood calculator above for your own sizes.
Find the log’s volume as a cylinder (π × radius² × length, in feet) and divide by about 80 cubic feet of solid wood per cord. A log 16 inches across and 8 feet long holds about 11.2 cubic feet, or roughly 0.14 cord. Allow for waste from bark, trimming and splitting, so the real amount is a little less.
Dense hardwoods such as hickory, black locust and oak give the most heat per cord — about 26–29 million BTU, compared with about 15 million for white pine or basswood (University of Kentucky, wood at 20% moisture). Softwoods and light hardwoods burn faster and are handy for starting fires. See the species table above.
Wood should read 20% moisture or less before you burn it. EPA advises at least 6 months of seasoning for softwood and at least 12 months for hardwood, with the wood split, stacked off the ground and covered on top. Burning wet wood gives less heat and increases creosote in the chimney.
It can be, but it depends on local prices, your wood supply and your appliance. Enter the price per cord and your current yearly fuel cost in the calculator to compare. Remember to include the cost and upkeep of the stove or insert, chimney maintenance, and the time to handle and stack wood.
Yes. This firewood calculator is free and works in your browser. It covers how many cords you need, tree and log yield, and cord, face cord and loose-pile conversions, with no sign-up.
Prakash — Founder and Editor of ConstructlyTools

Prakash

Founder & Editor
ConstructlyTools.com

Prakash is the founder and editor of ConstructlyTools. He researches, develops, and maintains construction calculators, material estimators, cost guides, and DIY planning resources designed to help homeowners, contractors, and builders make informed project decisions.

Every calculator and guide is researched using trusted industry references, published building standards, manufacturer specifications, and reliable construction pricing sources. Each page is reviewed for formula accuracy, pricing methodology, readability, and practical usefulness before publication and is updated regularly as standards or market prices change.

Formula Accuracy Verified 2026 Pricing Reviewed Industry Sources Referenced Updated Regularly
Last reviewed: October 13, 2026
Professional Highlights
Founder of ConstructlyTools
Develops Construction Calculators
Researches Cost Estimation Data
Reviews Building Code References
Updates Pricing Annually
Focused on DIY Homeowners & Professionals
Editorial Review Process

Every calculator and article published on ConstructlyTools is reviewed by the editor for formula accuracy, pricing methodology, readability, and practical usefulness before publication. We use AI tools to help draft and format some content; every figure and formula is checked by the editor before publication. Content is updated whenever construction pricing, industry standards, or building code references significantly change.

This page was researched, written, and reviewed in accordance with our Editorial Policy.

Scroll to Top