Firewood Calculator
Use this free firewood calculator to find how many cords you need for the winter, based on the fuel you use now or the wood you burned last year. It also estimates firewood from a tree or a log, and converts cords, face cords, loose piles and cubic feet. Jump to the tree and log calculator or the cord converter. Quick answer: 1 full cord = 128 cubic feet of stacked wood (4 × 4 × 8 ft), and a 16-inch face cord is one-third of a cord.
- Firewood Calculator (How Many Cords?)
- Tree and Log to Firewood Calculator
- Cord Converter (Face Cord, Loose, Cubic Feet)
- Heat Value by Wood Species
- Worked Examples
- Buying and Measuring Firewood
- Seasoning, Storing and Burning Safely
- Common Mistakes
- How We Calculate
- Sources and References
- FAQs
- Related Tools
Cords = Heat needed ÷ (Million Btu per cord × Wood appliance efficiency) × (1 + extra %)
Estimates, not guarantees. Wood appliance efficiency and your home’s real heat loss vary, so keep the extra % for cold snaps. A cord is 128 cubic feet of stacked wood; ask sellers for the stacked volume.
Heat values are for wood seasoned to about 20% moisture.
Tree to Firewood and Log to Firewood Calculator
How much firewood is in a tree you plan to cut, or in a pile of logs? Choose standing trees (by trunk diameter) or cut logs (by diameter and length).
Tree estimates assume you use the main trunk and limbs down to about 4 inches in diameter (Cornell). Log estimates use the volume of a cylinder divided by about 80 cubic feet of solid wood per cord (range 65–90, University of Maryland); real yield is lower after bark, trimming and splitting waste. Freshly cut wood needs 6–12 months to season.
Cord of Firewood Converter — Face Cord, Loose Pile and Cubic Feet
Sellers use cords, face cords, truck loads and cubic feet. Enter the amount you were quoted to see the equal volume in stacked cords.
1 cord = 128 cu ft stacked (4 × 4 × 8 ft) · Face cord = 4 ft × 8 ft × the depth of one row of wood, so a 16-inch face cord is one-third of a cord and an 18-inch one is 37.5% · Loose piles: Maine’s legal “loose cord” is 180 cu ft for 12–16 in. pieces and 195 cu ft for 24 in. pieces; other places do not define it, so treat loose-pile figures as a guide · 1 stere (1 cubic meter) ≈ 0.276 cord
Firewood Heat Value by Species
Heavier hardwoods hold more heat per cord, so you need fewer of them. The table shows the heat in a full cord of wood seasoned to 20% moisture, its approximate dry weight, and how many cords of that species equal one cord of red oak.
| Species | Million BTU per Cord | Weight per Cord | Cords = 1 Cord Red Oak |
|---|---|---|---|
| Hickory | 29.3 | 3,560 lb | 1.13 |
| Black locust | 28.3 | 3,440 lb | 1.09 |
| White oak | 27.9 | 3,392 lb | 1.08 |
| Beech | 26.3 | 3,144 lb | 1.02 |
| Sugar maple | 25.9 | 3,144 lb | 1.00 |
| Red oak | 25.9 | 3,144 lb | 1.00 |
| White ash | 24.6 | 2,992 lb | 0.95 |
| Black walnut | 22.6 | 2,744 lb | 0.87 |
| Black cherry | 20.5 | 2,496 lb | 0.79 |
| American elm | 20.5 | 2,496 lb | 0.79 |
| Sycamore | 20.2 | 2,448 lb | 0.78 |
| Silver maple | 19.3 | 2,344 lb | 0.75 |
| Virginia pine | 20.7 | 2,400 lb | 0.80 |
| Yellow-poplar | 17.3 | 2,096 lb | 0.67 |
| Hemlock | 17.3 | 2,000 lb | 0.67 |
| Basswood | 15.2 | 1,848 lb | 0.59 |
| White pine | 15.0 | 1,744 lb | 0.58 |
Values are for eastern species from the University of Kentucky table. Other sources, such as the University of Maryland, give slightly different numbers (for example, oak at 25.3 million BTU), because wood varies by tree, region and moisture. For western or other species not listed, pick the “Custom” option and use your supplier’s heat value, or the EIA average of 20 million BTU per cord.
Wood that is not seasoned loses heat to boiling off water. Always burn wood at 20% moisture or less (check with a moisture meter), and treat the table as the heat you get from dry wood only.
Worked Examples
Example 1 — Replacing Half of an Oil Furnace’s Heat
Heat delivered by oil: 800 × 138,500 Btu × 0.80 = 88.64 million Btu
Heat needed from wood: 88.64 × 0.50 = 44.32 million Btu
Cords: 44.32 ÷ (25.9 × 0.70) = 2.44 cords; with 10% extra = 2.7 cords (about 8.1 face cords)
Example 2 — Switching Species
3 × 15.0 ÷ 25.9 = 1.74 cords of oak for the same heat; add 10% = 1.9 cords
Example 3 — Trees on Your Lot
6 × 0.33 = 1.98 cords
Example 4 — A Cut Log
Volume = π × (8 ÷ 12)² × 8 = 11.2 cu ft
Cords ≈ 11.2 ÷ 80 = 0.14 cord (range 0.12–0.17 cord using 90 and 65 cu ft of solid wood per cord)
Example 5 — A Loose Pile
180 ÷ 180 = 1 stacked cord (using Maine’s loose-cord definition). Re-stack to check.
For the cost of a stove or insert, see our Fireplace Insert Cost Calculator.
Buying and Measuring Firewood
- Ask for the volume in cubic feet or full cords. A full cord is 128 cubic feet of wood stacked tightly (4 ft high × 4 ft deep × 8 ft long). Most US states define the cord by law.
- Know what a “face cord” is. It is 4 ft × 8 ft by the depth of one row, commonly 16 inches (one-third of a cord) but sometimes up to 24 inches. Words like “rick” and “stove cord” have no single legal meaning.
- Measure the delivered stack. Stack it tightly, then multiply length × height × depth in feet and divide by 128.
- Check the moisture. Aim for 20% or less on a moisture meter. Gray, cracked ends and peeling bark suggest dry wood; heavy, wet or green wood needs a season or more.
- Get a receipt showing the volume, species and price, and compare prices per full cord, not per load.
- Buy local. Many places restrict moving firewood to limit the spread of tree pests; ask your state forestry agency.
Seasoning, Storing and Burning Firewood Safely
- Season it. EPA advises at least 6 months for softwood and at least 12 months for hardwood, split to pieces about 6 inches across or smaller.
- Stack it right. Keep wood off the ground, split side down, with air flowing through the stack and the top covered against rain and snow, but not the sides.
- Burn dry wood only. Wet wood gives less heat and raises the risk of creosote build-up, which can cause a chimney fire.
- Use a certified appliance. EPA says certified stoves use about one-third less wood for the same heat, and an open fireplace is a very inefficient way to heat a home.
- Maintain the chimney. Have the chimney and flue inspected before the heating season (see our Chimney Repair Cost Calculator), keep working smoke and carbon monoxide alarms, and follow your appliance manual and local code.
Wood heating carries fire and carbon monoxide risks. This page is general guidance. Have solid-fuel appliances installed and inspected by a qualified professional and follow local code and your insurer’s requirements.
Common Mistakes When Estimating Firewood
- Mixing up a face cord and a full cord. A 16-inch face cord is one-third of a cord, so three face cords equal one cord.
- Assuming all wood heats equally. A cord of pine can hold about half the heat of a cord of hickory.
- Ignoring appliance efficiency. The same cord gives far less useful heat in an open fireplace than in an EPA-certified stove.
- Buying green wood and burning it right away. Plan for 6–12 months of seasoning.
- Forgetting the cold snaps. Keep 10–20% extra, since a cold winter can use far more than an average one.
- Counting loose piles as cords. Loose wood contains more air than a tight stack; re-stack to check what you got.
- Overestimating trees. The tree table assumes you use the trunk and limbs down to 4 inches and ignores waste.
How We Calculate
Fuel-based estimate. We convert your fuel into the heat it delivered: Fuel × Btu per unit × system efficiency. The Btu values come from EIA: heating oil 138,500 Btu per gallon, propane 91,452 Btu per gallon, natural gas 1,036 Btu per cubic foot (103,600 per ccf) and electricity 3,412 Btu per kWh. The default efficiencies (80% for combustion furnaces, 100% for electric resistance) are typical values you can change to match your equipment.
Wood needed. Cords = Heat from wood ÷ (Million Btu per cord × Wood appliance efficiency), then plus your extra percentage. Heat content by species is from the University of Kentucky table (wood at 20% moisture). Appliance presets of about 70% (EPA-certified), 50% (older stove) and 10% (open fireplace) are planning values; EPA notes that advertised stove efficiency is usually combustion efficiency and the overall figure may be 10–20% lower, so use a lower custom value if unsure.
Last winter’s wood. Cords this winter = Last winter’s cords × (Last species’ Btu ÷ New species’ Btu), plus extra. It assumes the same appliance and weather.
Trees. Cords per tree come from the Cornell Cooperative Extension table, built from USDA Forest Service NED-2 volume data (6 in. = 0.03 cord up to 22 in. = 1.0 cord). We interpolate between diameters and extend the last slope above 22 inches.
Logs. Volume = π × (diameter ÷ 2 in feet)² × length, divided by 80 cu ft of solid wood per cord (range 65–90).
Converter. 1 cord = 128 cu ft; face cord = depth ÷ 48 of a cord; 1 stere = 0.276 cord (1 ÷ 3.62); loose piles use Maine’s legal loose cords (180 cu ft for 12–16 in., 195 cu ft for 24 in.) as a guide.
We use AI tools to help draft and format some content. The figures on this page come from the published sources listed below, and the formulas and examples were checked before publication. See our editorial policy.
Sources and References
The figures on this page were checked against the sources below in October 2026.
- University of Kentucky Forestry — Comparison of Properties Affecting Firewood: million BTU and weight per cord by species at 20% moisture.
- University of Maryland Extension — Buying and Storing Firewood and Pellets (FS-937): cord and face cord definitions, 65–90 cu ft of solid wood per cord, seasoning and moisture guidance.
- Cornell Cooperative Extension — Estimating the Volume of Firewood in a Tree: cords per tree by diameter, from USDA Forest Service NED-2 volumes.
- U.S. EIA — British Thermal Units (Btu): Btu content of heating oil, propane, natural gas, electricity and wood.
- Wikipedia — Cord (unit): the 128 cubic-foot cord, face cord, Maine’s loose cord definition and the stere conversion.
- U.S. EPA — Wood heating guidance: seasoning times, 20% moisture target, certified-stove benefits and efficiency caveats.
Published figures vary by source, species and region, so use these as a planning guide. ConstructlyTools has no paid relationship with any seller or manufacturer mentioned.
Frequently Asked Questions
Plan your winter heating and home-efficiency projects with these free tools.
Heating & Energy
Fireplace & Outdoor
Prakash
Prakash is the founder and editor of ConstructlyTools. He researches, develops, and maintains construction calculators, material estimators, cost guides, and DIY planning resources designed to help homeowners, contractors, and builders make informed project decisions.
Every calculator and guide is researched using trusted industry references, published building standards, manufacturer specifications, and reliable construction pricing sources. Each page is reviewed for formula accuracy, pricing methodology, readability, and practical usefulness before publication and is updated regularly as standards or market prices change.
Every calculator and article published on ConstructlyTools is reviewed by the editor for formula accuracy, pricing methodology, readability, and practical usefulness before publication. We use AI tools to help draft and format some content; every figure and formula is checked by the editor before publication. Content is updated whenever construction pricing, industry standards, or building code references significantly change.
This page was researched, written, and reviewed in accordance with our Editorial Policy.
