Generator Size Calculator
Use this free generator size calculator to find what size generator you need for your home. Tick the appliances you want to run, and the tool adds up the running and starting watts, applies a safety margin, and shows the generator size to buy. It works for a portable generator or a whole-house setup, and you can check a generator you already own. Not sure what the two numbers mean? Read running watts vs. starting watts. Quick answer: add the running watts of everything you will use at once, then add the extra starting watts of the single biggest motor. Motors can need three to five times their running watts to start, so a generator must cover both numbers. Always run a generator outdoors, at least 20 feet from doors, windows and vents.
Tick everything you want to power at the same time. The running watts and starting multiplier are typical values you can edit; check the data tag on your own appliances for exact numbers.
| Use | Appliance | Running Watts | Starting Multiplier | Starting Watts |
|---|---|---|---|---|
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — | ||||
| — |
Starting watts = Running watts + the largest extra surge of any single item
Extra surge = Running watts × (Starting multiplier − 1)
Generator rating = Watts × (1 + Safety margin)
Already Have a Generator in Mind? Check It
Enter the two ratings from the generator’s label to see whether it can run your list.
A generator must cover both numbers: its running rating must be above your running watts, and its starting (peak) rating above your starting watts. Round up to the next available model.
Typical wattages vary a lot between models, so treat the checklist as a starting point and replace it with the numbers on your appliance labels where you can.
Find an Appliance’s Running and Starting Watts
If an appliance is not in the list, find its volts and amps on the data tag. The running watts are volts × amps. If the tag lists the starting (locked-rotor or inrush) current, enter it to get the starting watts; otherwise pick a multiplier.
Starting watts = Volts × Starting amps, or Running watts × Starting multiplier
The rating plate of a motor-driven appliance may list starting current, locked-rotor amps (LRA) or inrush current. Use that figure when you have it.
Running Watts vs. Starting Watts
- Running watts are what an appliance draws while it operates.
- Starting watts are the brief surge motors and compressors need to get going. Cummins says starting power can be three, four or even five times the running power, so a generator that cannot start a load cannot run it.
- Count the surge once. Cummins’ method adds the starting watts of the single largest motor load to the running watts of all the other loads, because not everything starts at the same moment. Adding every starting figure would overstate what you need.
- Check both ratings. The generator’s running rating should be above your running watts, and its surge (peak) rating above your starting watts.
- Check the voltage. If any load needs 240 V, or the generator will connect to a panel, choose a 120/240 V generator.
- Add a margin. Cummins does not specify a percentage; we default to 20% so the generator is not run at its limit. An undersized generator can shut down on overload and may damage its electronics.
1 kilowatt (kW) = 1,000 watts, and watts = volts × amps. A 3,500 W generator is a 3.5 kW generator. For a whole-house load calculation by circuit, use our Electrical Load Calculator.
Portable and Whole-House Generator Size Guide
The same method sizes a portable generator for an outage and a whole-house generator for a full home. The difference is how many items are on your list. These totals use the calculator’s typical values (before the safety margin):
| What You Run | Running Watts | Starting Watts | Note |
|---|---|---|---|
| Fridge, furnace fan and lights | 1,350 W | 2,850 W | Keeps food cold and the furnace blower running |
| Plus sump pump and television | 2,750 W | 4,750 W | Our default checklist |
| Plus well pump, microwave and coffee maker | 6,450 W | 8,450 W | Adds water and a kitchen |
| Plus 3-ton central A/C (240 V) | 12,450 W | 24,450 W | Needs a 120/240 V generator and an electrician |
Portable Generator Size
A portable generator suits a short list of essentials: the refrigerator, furnace fan, sump pump, lights and a few small items. Keep the list to what you must run, and stagger big motors rather than starting them together.
Whole-House Generator Size
To size a whole-house generator, tick every large load you want covered: the well pump, water heater, range, dryer and central air or heat pump. Those 240 V loads push the total into the thousands of watts, so you will want a 120/240 V unit connected by a licensed electrician. For installed costs, see our Whole-House Generator Cost Calculator; to check that your panel can handle it, see the Electrical Panel Upgrade Cost Calculator.
Space Heaters on a Generator
A plug-in heater is a large load: a 1,500 W heater adds 1,500 W to your running total. Size the heater first with our Room Heater Size Calculator.
Generator Safety
Carbon monoxide (CO) is the main danger. The U.S. Consumer Product Safety Commission (CPSC) estimates that an average of nearly 100 consumers die in the U.S. each year from CO poisoning from portable generators.
- Run it outdoors only. Never run a generator inside a home, garage, basement, crawlspace or shed, even with doors or windows open, and not on a porch or in a carport.
- Keep it 20 feet away from doors, windows and vents, with the exhaust pointed away from the house.
- Install CO alarms with battery backup (certified to UL 2034, IAS 6-96 or CSA 6.19.01) and test them monthly.
- Choose a model with a CO shut-off. CPSC advises models that shut off automatically when CO is high, such as those certified to UL 2201 or PGMA G300-2018.
- Never backfeed. Do not plug a generator into a wall outlet to power the house wiring. It can electrocute utility workers and neighbors. To power the house wiring, use equipment installed by a licensed electrician.
- Use proper cords. Heavy-duty cords rated for outdoor use, with a wattage rating above the load, and no cuts or tears.
- Keep it dry. Run it on a dry surface under an open, canopy-like structure, and dry your hands before touching it.
- Refuel safely. Turn it off and let it cool first, and store fuel outside living areas in labeled, non-glass containers.
Carbon monoxide is colorless and odorless. If you feel dizzy, weak or sick while a generator is running, get to fresh air right away and call for help.
Worked Examples
Example 1 — Winter Outage Essentials
Running watts = 750 + 450 + 1,000 + 150 + 400 = 2,750 W
Extra surge: refrigerator 1,500 W, furnace fan 900 W, sump pump 2,000 W; the largest is the sump pump’s 2,000 W
Starting watts = 2,750 + 2,000 = 4,750 W
With a 20% margin: 3,300 W running and 5,700 W starting. Adding every starting figure instead would give 7,150 W, which overstates the need.
Example 2 — Does This Generator Work?
Running: 2,750 W is within 3,500 W, with 750 W to spare.
Starting: 4,750 W is more than 4,000 W, so it is short by 750 W. It would likely struggle to start the sump pump while the other loads run. Pick a model with a higher starting rating, or stagger the loads.
Example 3 — Watts From the Data Tag
Running watts = 120 × 8 = 960 W
Starting watts at a ×3 multiplier = 960 × 3 = 2,880 W
Example 4 — Adding a Space Heater
Running watts = 2,750 + 1,500 = 4,250 W
Starting watts = 4,250 + 2,000 = 6,250 W (the sump pump is still the largest surge)
Common Mistakes When Sizing a Generator
- Sizing only for running watts. Motors need the starting surge too.
- Adding every starting surge. Only the single largest surge is added on top of the running total.
- Listing everything in the house. Only count what you will run at the same time.
- Forgetting 240 V loads. A water heater, dryer, range, central A/C or heat pump needs a 120/240 V generator.
- No margin. Running a generator at its limit invites overload shutoffs.
- Trusting generic wattage charts. Published figures vary between sources and models; use the appliance label.
- Running it too close to the house. Keep it outdoors and at least 20 feet from doors, windows and vents.
How We Calculate
Running watts. The sum of the running watts of every ticked item.
Starting watts. Running watts plus the largest single extra surge, where extra surge = running watts × (multiplier − 1). This matches the Cummins method of adding the largest motor’s starting watts to the running watts of the other loads.
Typical values. The default running watts and starting multipliers come from DTE Energy’s appliance usage guide. Sources differ: A&M Industrial lists a sump pump at 2,100 W running, while DTE lists a 1/2 HP submersible at 1,000 W. That is why every value is editable, and why your own appliance label wins. Where DTE gives a range (lights, television, microwave, coffee maker), we use a value within it.
Safety margin. Generator rating = Watts × (1 + margin). The 20% default is our planning choice, not a published standard.
Limits. This is a sizing estimate. It does not account for altitude, fuel type, power factor or the exact starting behavior of your appliances. Ask an electrician before connecting a generator to your home’s wiring.
We use AI tools to help draft and format some content. The figures on this page come from the published sources listed below, and the formulas and examples were checked before publication. See our editorial policy.
Frequently Asked Questions
Plan for winter outages with these free tools.
Backup Power & Electrical
Heating & Winter Prep
Sources and References
The figures on this page were checked against the sources below in October 2026.
- Cummins — What size portable generator do you need? Here’s how to decide: running vs. starting power, starting power of three to five times running power, and adding only the largest starting load.
- DTE Energy — Appliance Usage Guide and worksheet: typical running watts and starting factors for household appliances, and the worksheet method.
- A&M Industrial — Generator Wattage Reference Guide: a second appliance wattage table, used to show how published figures differ.
- U.S. Consumer Product Safety Commission — Portable Generator Safety Alert: outdoor use, 20-foot distance, CO alarms, cords, refueling, backfeeding and dry operation.
- U.S. Consumer Product Safety Commission — Winter storm safety tips (January 10, 2024): nearly 100 CO deaths a year from portable generators, placement, and CO shut-off models.
Appliance and generator ratings vary by product, so use the labels on your own equipment. ConstructlyTools has no paid relationship with any manufacturer or retailer mentioned.
Prakash
Prakash is the founder and editor of ConstructlyTools. He researches, develops, and maintains construction calculators, material estimators, cost guides, and DIY planning resources designed to help homeowners, contractors, and builders make informed project decisions.
Every calculator and guide is researched using trusted industry references, published building standards, manufacturer specifications, and reliable construction pricing sources. Each page is reviewed for formula accuracy, pricing methodology, readability, and practical usefulness before publication and is updated regularly as standards or market prices change.
Every calculator and article published on ConstructlyTools is reviewed by the editor for formula accuracy, pricing methodology, readability, and practical usefulness before publication. We use AI tools to help draft and format some content; every figure and formula is checked by the editor before publication. Content is updated whenever construction pricing, industry standards, or building code references significantly change.
This page was researched, written, and reviewed in accordance with our Editorial Policy.